Spirometar klinički Alpha Touch

Šifra artikla: DU157

Tehničke karakteristike:

  • Fleisch Pneumotachograph – trenutno svjetski najbolja tehnologija za mjerenje protoka
  • Jednostavan grafički izbornik na ekranu u boji
  • Ekran osjetljiv na dodir
  • Memorijski kapacitet za 10.000 subjekata
  • Preko 50 parametara
  • Ispisivanje F/V i/ili V/T krivulja
  • Usporedba pred i post bronhodilatatornih testova
  • Baterijsko napajanje uređaja
  • Prilagodljivi rezultati testova
  • Integrirani printer
  • Parametri:
  • VC            Vital capacity (L)
  • IVC          Inspiratory vital capacity (L)
  • FIVC        Forced inspiratory vital capacity (L)
  • FVC          Forced vital capacity (L)
  • FEV.5       Forced expiratory volume after 0.5 seconds (L)
  • FEV.75     Forced expiratory volume after 0.75 seconds (L)
  • FEV1        Forced expiratory volume after 1 second (L)
  • FEV3        Forced expiratory volume after 3 seconds (L)
  • FEV6        Forced expiratory volume after 6 seconds (L)
  • PEF L/s     Peak expiratory flow (L/sec)
  • PEF L/min            Peak expiratory flow (L/min)
  • FEF0.2-1.2           Mean forced expiratory flow in the volume interval between 0.2 and 1.2 L of the test (L/sec)(F02-12)
  • FEF 25-75            Maximal mid expiratory flow: the mean FEF in the time interval between 25% and 75% of the FVC (L/sec) (F2575)
  • FEF 75-85            Forced late expiratory flow: the mean FEF in the time interval between 75% and 85% of the FVC (L/sec) (F7585)
  • FEF 25      Forced expiratory flow at 25% of the FVC (L/sec)
  • FEF 50      Forced expiratory flow at 50% of the FVC (L/sec)
  • FEF 75      Forced expiratory flow at 75% of the FVC (L/sec)
  • FIV1         Forced inspiratory volume after 1 second (L)
  • PIF L/s      Peak inspiratory flow (L/sec)
  • FIF 25       Forced inspiratory flow at 25% of the FVC (L/sec)
  • FIF 50       Forced inspiratory flow at 50% of the FVC (L/sec)
  • FIF 75       Forced inspiratory flow at 75% of the FVC (L/sec)
  • MVVind   Maximum voluntary ventilation indirectly calculated from the FEV1 (L/min)
  • FMFT       Forced mid-expiratory flow time (sec)
  • FET           Forced expiratory time (sec)
  • Vext          Extrapolated volume (L)
  • FRC          Functional residual capacity (L)
  • TV             Tidal volume (L)
  • RV             Residual volume (L)
  • TLC          Total lung capacity (L)
  • IRV          Inspiratory reserve volume (L)
  • ERV         Expiratory reserve volume (L)
  • IC              Inspiratory capacity (L)
  • Rind          Airways Resistance Indirect measurement.
  • FIVC/FVC           Ratio FIVC of FVC
  • FEV.5/FVC          Ratio FEV 0.5 of FVC
  • FEV1/FEV6         Ratio FEV1 of FEV6
  • FEV1/FVC           Ratio FEV1 of FVC
  • FEV1/VC             Ratio FEV1 of VC
  • FEV1/PEF           FEV1 divided by PEF (L/L/s)
  • FEV3/VC             Ratio FEV3 of VC
  • FEV3/FVC           Ratio FEV3 of FVC
  • FEF 25-75/FVC   Ratio FEF 25–75 of FVC (F2575/F)
  • FIV1/FVC              Ratio FIV1 of FVC
  • FIV1/FIVC          Ratio FIV1 of FIVC
  • FIF50FEF50        Ratio FIF 50% of FEF 50%
  • FEV75/FVC         Ratio FEV 0.75 of FVC
  • FEV1/FIVC         Ratio FEV1 of FIVC
  • FEV1/IVC            Ratio FEV1 of IVC
  • FEV1R                 FEV1 divided by the largest VC from the VC or FVC manoeuvre.
  • Vext/FVC             Ratio extrapolated volume of FVC
  • PIF L/min             Peak inspiratory flow (L/min)
  • Lung Age             Lung age will be displayed if the date of birth, height, population group and smoking information have been entered.  Lung age will only be shown if the measured FEV1 value is less than the lower limit of the predicted normal value for FEV1.

Video prezentaciju uređaja pogledajte u prozoru ispod: